Cyclonic device that uses superheated steam in order to separate hydrocarbon oils into two fractions.
Specifications
Superheated Steam Capacity:
Flow: 21 lbm/hr
Max Temperate: 1000 degF
Max Pressure: 250 Psig
Hydrocarbon Capacity:
Flow: 4.5 cc/rev
Max Temperature: 400 deg F
Max Pressure: 2500 Psig
VLSD Max Temperature:
MAWP: 250 Psig @ 750 degF
VLSD Furnace Capacity:
Duty: 36kW divided over three zones